PONOVO's PAV series of 4-quadrant simulation power amplifiers is based on linear power amplifier technology, and integrated advanced technical performance with rich functions. It is widely used by institutions in industries of power, new energy, aerospace, railway transportation, mining, petrochemical etc. It is also the ideal R&D device for wind power, PV, electric car, large power charging device, aerospace power system, marine power system, energy distribution and micro grid etc.
It can be directly connected to popular simulation platforms including RTDS, OPAL-RT, NI, Typhoon etc., supporting not only analog input communication, but also digital interface communication via AURORA protocol.
It can work as both source mode to output power and also sink power mode to conduct power absorption.
Models:
PAV3000 4-Quadrant Power Amplifier
PAV5000 4-Quadrant Power Amplifier
PAV10000 4-Quadrant Power Amplifier
PAV15000 4-Quadrant Power Amplifier
PAV20000 4-Quadrant Power Amplifier
PAV30000 4-Quadrant Power Amplifier
PIV270 Portable 4-Quadrant Power Amplifier
Power Amplifier DIA-01 Aurora Digital Module for Simulator Application
PAL Programmable AC Load Unit
PDL Programmable DC Load Unit
PADS Programmable AC&DC Power Supply Unit
Main Features:
- Extremely low harmonic distortion - even under very non-linear load conditions
- Very fast slew rate: >50V/μs
- Short Input/Output delay: <10μs
- Wide frequency range: DC~5kHz
- High input impedance
- High output precision
- High accuracy output
- Special port for power interactive simulation in 4-quadrant
- Supports optical digital communication with PHIL interface via AURORA protocol
- Dual-gain to work smoothly with different simulations
- Measurement, monitor and protection functions
- High long-term overload characteristic (up to 1 hour)
- High short-term overload characteristic (for 5-10 min)
Applications:
• The distributed energy system such as photovoltaic power generation, wind generation, energy storage battery and fuel cell system etc.
• The microgrid
• The electromobile and charge unit
• The energy storage
• Railway transportation
• The aerospace
• The electric system detection
• The hybrid simulation in power system
• HVDC
• FACTS
• HVDC and HVAC connection
• Dynamic load analysis on AC, etc.
Application Areas:
Distributed energy systems such as photovoltaic power generation, wind generation, energy storage battery and fuel cell system etc. |
Electric system detection
|
Microgrid |
Hybrid simulation in power systems |
Electromobile and charge units |
HVDC |
Energy storage |
FACTS |
Railway transportation |
HVDC and HVAC connection |
Aerospace |
Dynamic load analysis on AC, etc. |
Specifications: PAV3000 / PAV5000 / PAV10000
Model |
PAV3000 |
PAV5000 |
PAV10000 |
Nominal Voltage |
|
|
|
AC |
270V (135V optional) |
270V (135V optional) |
270V (135V optional) |
DC |
±382V (±191V optional) |
±382V (±191V optional) |
±382V (±191V optional) |
Line Regulation |
1.5×10-4 / 10V |
1.5×10-4 / 10V |
1.5×10-4 / 10V |
Gain |
25V/V; 40V/V (optional) |
25V/V; 40V/V (optional) |
25V/V; 40V/V (optional) |
Gain Stability (const load & Temp.) |
±0.1% / 5min |
±0.1% / 5min |
±0.1% / 5min |
Frequency Range |
|
|
|
Bandwidth range |
DC~5kHz (-3dB) |
DC~5kHz (-3dB) |
DC~5kHz (-3dB) |
Small signal (3%) |
DC~50kHz (-3dB) |
DC~50kHz (-3dB) |
DC~50kHz (-3dB) |
Harmonic Distortion |
|
|
|
45~450Hz (Typ. / Max.) |
0.05% / 0.2% |
0.05% / 0.2% |
0.1% / 1% |
450~5kHz |
0.6% typ., 1% guar. |
0.6% typ., 1% guar. |
0.6% typ., 1% guar. |
Input |
|
|
|
Signal Range (Analog Signal) |
0~±16V (25V/V) (optional)
0~±10V (40V/V) |
0~±16V (25V/V) (optional)
0~±10V (40V/V) |
0~±16V (25V/V) (optional)
0~±10V (40V/V) |
Digital Signal Interface |
Communication interface with fiber optic ports, supporting AURORA protocol |
Communication interface with fiber optic ports, supporting AURORA protocol |
Communication interface with fiber optic ports, supporting AURORA protocol |
Impedance |
10kΩ |
10kΩ |
10kΩ |
Input/Output Delay |
10μs |
10μs |
10μs |
Power AC (Nominal Voltage 270V) |
3kVA |
5kVA |
10kVA |
Power DC (Nominal Voltage ± 382V) |
3kW |
5kW |
10kW |
Long-time Overload (1 hour) |
4.5kVA |
7.5kVA |
15kVA |
Max. Short-time Power |
6kVA |
10kVA |
20kVA |
Max. Sink Power |
30% rated output power |
30% rated output power |
30% rated output power |
Measurement Range |
|
|
|
Voltage |
0~300V |
0~300V |
0~300V |
Current |
0~24A |
0~40A |
0~80A |
Accuracy of Voltage Measurement |
0.5% RG |
0.5% RG |
0.5% RG |
Accuracy of Current Measurement |
0.5% RG |
0.5% RG |
0.5% RG |
Accuracy of Power Measurement |
0.5% RG |
0.5% RG |
0.5% RG |
Protection |
Overload / Short-circuit / Overheat |
Overload / Short-circuit / Overheat |
Overload / Short-circuit / Overheat |
Digital Monitoring Unit (optional) |
|
|
|
Analog output |
0~±10V (±16 optional) |
0~±10V (±16 optional) |
0~±10V (±16 optional) |
Signal accuracy |
AC: 0.03% RG + 0.1% @ 0.5~6.75V
0.1% RG + 0.5% @ 0.1~0.5V
DC: 0.03% RG + 0.1% @ 0.5~9.55V
0.1% RG + 0.5% @ 0.1~0.5V |
AC: 0.03% RG + 0.1% @ 0.5~6.75V
0.1% RG + 0.5% @ 0.1~0.5V
DC: 0.03% RG + 0.1% @ 0.5~9.55V
0.1% RG + 0.5% @ 0.1~0.5V |
AC: 0.03% RG + 0.1% @ 0.5~6.75V
0.1% RG + 0.5% @ 0.1~0.5V
DC: 0.03% RG + 0.1% @ 0.5~9.55V
0.1% RG + 0.5% @ 0.1~0.5V |
Frequency output range |
0~5000Hz |
0~5000Hz |
0~5000Hz |
Frequency accuracy |
Accuracy (DC):
15 Hz~450Hz, ±0.02 Hz
450Hz~2000Hz, ±0.1Hz
2000Hz~5000Hz, ±0.15Hz |
Accuracy (DC):
15 Hz~450Hz, ±0.02 Hz
450Hz~2000Hz, ±0.1Hz
2000Hz~5000Hz, ±0.15Hz |
Accuracy (DC):
15 Hz~450Hz, ±0.02 Hz
450Hz~2000Hz, ±0.1Hz
2000Hz~5000Hz, ±0.15Hz |
Selectable waveforms (optional) |
DC, sine, square, triangle, ramp, arbitrary |
DC, sine, square, triangle, ramp, arbitrary |
DC, sine, square, triangle, ramp, arbitrary |
Power supply |
3 phase 380V/208V±10%,
50/60±5Hz |
3 phase 380V/208V±10%,
50/60±5Hz |
3 phase 380V/208V±10%,
50/60±5Hz |
Power protection |
short-circuit,
defaut-phase alarm |
short-circuit,
defaut-phase alarm |
short-circuit,
defaut-phase alarm |
Dimensions |
|
|
|
Cabinet (W × D × H) |
650mm × 900mm × 2100mm, 43U |
650mm × 900mm × 2100mm, 43U |
650mm × 900mm × 2100mm, 43U |
Power amplifier unit |
19'', 5U |
19'', 5U |
19'', 11U |
Digital monitor unit |
19'', 4U |
19'', 4U |
19'', 4U |
Power supply unit |
19'', 12U |
19'', 12U |
19'', 12U |
Weight |
450kg |
450kg |
3 × 450kg |
*Note: The default frequency is 50Hz/60Hz except for the explicitly indicated frequency.
Specifications: PAV15000 / PAV20000 / PAV30000
Model |
PAV15000 |
PAV20000 |
PAV30000 |
Nominal Voltage |
|
|
|
AC |
270V (135V optional) |
270V (135V optional) |
270V (135V optional) |
DC |
±382V (±191V optional) |
±382V (±191V optional) |
±382V (±191V optional) |
Line Regulation |
1.5×10-4 / 10V |
1.5×10-4 / 10V |
1.5×10-4 / 10V |
Gain |
25V/V; 40V/V (optional) |
25V/V; 40V/V (Could be customized set, optionally) |
25V/V; 40V/V (Could be customized set, optionally) |
Gain Stability (const load & Temp.) |
±0.1% / 5min |
±0.1% / 5min |
±0.1% / 5min |
Frequency Range |
|
|
|
Bandwidth range |
DC~5kHz (-3dB) |
DC~5kHz (-3dB) |
DC~5kHz (-3dB) |
Small signal (3%) |
DC~50kHz (-3dB) |
DC~40kHz (-3dB) |
DC~40kHz (-3dB) |
Harmonic Distortion |
|
|
|
45~450Hz (Typ. / Max.) |
0.1% / 1% |
0.5% / 1.5% |
0.5% / 1.5% |
450~5kHz |
1% typ., 2% guar. |
1% typ., 2% guar. |
1% typ., 2% guar. |
Input |
|
|
|
Signal Range (Analog Signal) |
0~±16V (25V/V) (optional)
0~±10V (40V/V) |
0~±16V (25V/V) (optional)
0~±10V (40V/V) |
0~±16V (25V/V) (optional)
0~±10V (40V/V) |
Digital Signal Interface |
Communication interface with fiber optic ports, supporting AURORA protocol |
Communication interface with fiber optic ports, supporting AURORA protocol |
Communication interface with fiber optic ports, supporting AURORA protocol |
Impedance |
10kΩ |
10kΩ |
10kΩ |
Input/Output Delay |
10μs |
10μs |
10μs |
Power AC (Nominal Voltage 270V) |
15kVA |
20kVA |
30kVA |
Power DC (Nominal Voltage ± 382V) |
15kW |
20kW |
30kW |
Long-time Overload (1 hour) |
22.5kVA |
30kVA |
45kVA |
Max. Short-time Power |
30kVA |
40kVA |
60kVA |
Max. Sink Power |
30% rated output power |
30% rated output power |
30% rated output power |
Measurement Range |
|
|
|
Voltage |
0~300V |
0~300V |
0~300V |
Current |
0~120A |
0~200A |
0~300A |
Accuracy of Voltage Measurement |
0.5% RG |
0.5% RG |
0.5% RG |
Accuracy of Current Measurement |
0.5% RG |
0.5% RG |
0.5% RG |
Accuracy of Power Measurement |
0.5% RG |
0.5% RG |
0.5% RG |
Protection |
Overload / Short-circuit / Overheat |
Overload / Short-circuit / Overheat |
Overload / Short-circuit / Overheat |
Digital Monitoring Unit (optional) |
|
|
|
Analog output |
0~±10V (±16 optional) |
0~±10V (±16 optional) |
0~±10V (±16 optional) |
Signal accuracy |
AC: 0.03% RG + 0.1% @ 0.5~6.75V
0.1% RG + 0.5% @ 0.1~0.5V
DC: 0.03% RG + 0.1% @ 0.5~9.55V
0.1% RG + 0.5% @ 0.1~0.5V |
AC: 0.03% RG + 0.1% @ 0.5~6.75V
0.1% RG + 0.5% @ 0.1~0.5V
DC: 0.03% RG + 0.1% @ 0.5~9.55V
0.1% RG + 0.5% @ 0.1~0.5V |
AC: 0.03% RG + 0.1% @ 0.5~6.75V
0.1% RG + 0.5% @ 0.1~0.5V
DC: 0.03% RG + 0.1% @ 0.5~9.55V
0.1% RG + 0.5% @ 0.1~0.5V |
Frequency output range |
0~5000Hz |
0~5000Hz |
0~5000Hz |
Frequency accuracy |
Accuracy (DC):
15 Hz~450Hz, ±0.02 Hz
450Hz~2000Hz, ±0.1Hz
2000Hz~5000Hz, ±0.15Hz |
Accuracy (DC):
15 Hz~450Hz, ±0.02 Hz
450Hz~2000Hz, ±0.1Hz
2000Hz~5000Hz, ±0.15Hz |
Accuracy (DC):
15 Hz~450Hz, ±0.02 Hz
450Hz~2000Hz, ±0.1Hz
2000Hz~5000Hz, ±0.15Hz |
Selectable waveforms (optional) |
DC, sine, square, triangle, ramp, arbitrary |
DC, sine, square, triangle, ramp, arbitrary |
DC, sine, square, triangle, ramp, arbitrary |
Power supply |
3 phase 380V/208V±10%,
50/60±5Hz |
3 phase 380V/208V±10%,
50/60±5Hz |
3 phase 380V/208V±10%,
50/60±5Hz |
Power protection |
short-circuit,
defaut-phase alarm |
short-circuit,
defaut-phase alarm |
short-circuit,
defaut-phase alarm |
Dimensions |
|
|
|
Cabinet (W × D × H) |
650mm × 900mm × 2100mm, 43U |
On request |
On request |
Power amplifier unit |
19'', 17U |
On request |
On request |
Digital monitor unit |
19'', 4U |
On request |
On request |
Power supply unit |
19'', 12U |
On request |
On request |
Weight |
3 × 450kg, 1 × 280kg |
On request |
On request |
*Note: The default frequency is 50Hz/60Hz except for the explicitly indicated frequency.
PIV270 Portable 4-Quadrant Power Amplifier
PONOVO Power's PIV270 Portable 4-Quadrant Power Amplifier is equipped with features of high power, large current, high voltage, high precision, high speed etc. It can meet different applications on power and precision requirements. The platform co-work with different simulators as to build a PHIL (Power Hardware in Loop) simulation. It can easily, quickly and efficiently build a variety of simulating and testing application scenarios, including power systems; new energy; electric vehicles and charging facilities; Micro-grid, Distributed Energy; Railway Transit; Industrial Robots; High Power Semiconductors; Aviation and aerospace power; ship power etc.
It is with 3-phase voltage output and 4-Quadrant design principle which can be used for amplifier mode to drive active load, reactive load, capacitive load, inductive load, etc.
It can also be used for sink mode to do power absorption to finalize the PHIL simulation together with simulator and other physical equipment.
It also supports digital interface communication via AURORA protocol so that only fiber cable connection shall be required between the simulator and PIV270. In this way, the communication speed shall be very fast to finalize more real-time applications.
PIV270 Specifications
Voltage Output Mode (CV Mode) |
Output Range |
AC: 3×0~135/270V RMS |
|
DC: 0~382V |
Output Accuracy |
0.1% |
Gain |
38.5V/V |
Bandwidth Range |
DC~5kHz -1dB |
Harmonic Distortion (THD%) |
45Hz~450Hz: 0.05% |
|
450Hz~5kHz: 0.2% |
Slew Rate |
38V/μs |
Input/Output Time Delay |
<6μs |
Rated Output Power |
AC: 300VA |
|
DC: 300W |
Max. Sink Power |
30% rated output power |
Constant Current Output Mode (CC Mode) |
Output Range |
AC: 3×0~1A RMS |
|
DC: 0~1A |
Output Accuracy |
0.5% |
Gain |
0.145A/V |
Bandwidth Range |
DC~5kHz -2dB |
Harmonic Distortion (THD%) |
45Hz~65Hz: 0.5% |
Slew Rate |
0.1A/μs |
Input/Output Time Delay |
<10μs |
Rated Output Power |
AC: 270VA |
|
DC: 270W |
Measurement Range |
Voltage Range |
AC: 3×0~270V RMS |
|
DC: 0~382V |
Current Range |
AC: 3×0~1A RMS |
|
DC: 0~1A |
Input/Output Time Delay |
<3μs |
Digital Signal Interface |
Interface |
via AURORA protocol communication |
Power Supply |
Input |
85~264V AC |
Frequency |
50/60Hz |
OR DC Input |
180V~300V DC |
Dimensions (4U) |
H×W×D (mm) |
210mm×510mm×385mm |
Weight |
18.35kg |
Power Amplifier DIA-01 Aurora Digital Module For Simulator Application
PAV DIA01 is an optional accessory unit for PONOVO's power amplifiers which can convert analog input signal into digital signal, supporting communication between power amplifier and simulators via AURORA protocol. Via the Aurora port, it communicates with the real-time dynamic system, and then converts the received digital signal into analog signal with output to the power amplifier unit.
The digital signal, converted from the voltage/ current signal by the power amplifier, will be transmitted to the real-time dynamic system. The Aurora will function as the bridge of the closed loop in the system.
PAL Programmable AC Load Unit
The programmable AC load can simulate the voltage and current power characteristics of the compressor, AC motor and other AC load on the EV. It can beused to test AC charging pile, EV inverter etc. It adopts closed-loop control with high precision.
It support either 3-phase independent operation, single-phase or 3-phase operation, local or remote operation. Alloy resistance wire was used with light weight, low temperature drift, no red heat phenomenon.
It is with Modular design, 19-inch 8U high chassis, which can be expanded in parallel.
And it is rugged case adapt harsh environment for site using.
Also Modules can be integrated in cabinet for lab using.
Application example
AC Charging Pile Auto-test
AC Charging Pile: The special power supply device which adopted conductive method to provide AC power source to EV with on- board charger.
On-Board Inverter Auto-Test
The programmable AC load can simulate the voltage and current power characteristics of the compressor, AC motor and other AC load on the EV. It can be used to test AC charging pile, EV inverter etc. It adopts closed-loop control with high precision.
PDL Programmable DC Load Unit
The programmable DC load can simulate the voltage and current power characteristics of the electric vehicle's power battery, and carries out the load test on the DC charging pile. It can also simulate the characteristics of auxiliary battery or DC motor to test on-board DC-DC. The working mode can be constant voltage, constant current, constant power and constant resistance. It adopts closed-loop control with high precision.
Features:
- Switching devices use high-speed IGBT devices to achieve micro-second (us) level switching;
- High speed and stepless regulation in constant voltage and constant current modes.
- Nickel-chromium alloy material resistance was used, which is light in weight, high in working temperature and free from red heat;
- Modular design, 19-inch 5U high chassis. Host/slave integrated design.
- Rugged case adapt harsh environment for site using.
Off-Board Charger Auto-Test
Off-board charger (DC charging pile): The special power supply device installed outside of the EV and convert AC power into DC to charge EV traction battery with conductive method.
On-Board DC-DC Auto-Test
Programmable DC source can provide 400~1000V high voltage to test On-board DC-DC, at this moment DC load simulates 12V or 48V auxiliary battery load.
PADS Programmable AC&DC Power Supply Unit
The energy feedback type programmable AC/DC power source with energy feedback unit equipped functions of voltage adjustable, frequency adjustable, harmonic controllable, low voltage ride through simulation etc.
The product is ideal tools for research and development of photovoltaic/storage inverters, converters, rectifiers, DC power supplies, DC-DC converters, UPS/EPS, motor/generators, power transformers, chargers/piles, batteries, electronic products, etc. It can be used in the production commissioning, factory inspection, laboratory electrical characteristics testing, authoritative organization identification testing and other fields.
Features:
- With energy feedback function, it can provide 100% rated power recovery.
- Output frequency 0-100Hz, step size 0.01Hz.
- Internal waveform synthesizer, can realize any sub-harmonic superposition function (up to 50 harmonics at maximum).
- Equipped with over-current, over-voltage, over-heat, over-load and short circuit protection etc.
- A variety of communication interfaces, including RS485, RS232, and Ethernet ports.
- Can be connected by shielded twisted pair cables and network cables, Modbus protocol is available.
Functions:
The power supply output is controlled by the host computer software, and the software can run on Windows XP and Win7. By adjusting the amplitude and phase of the output voltage, voltage disturbance, frequency,disturbance, harmonic disturbance, three-phase unbalanced disturbance, fluctuation and flicker disturbance performance can be tested.
EV AC Charging Function-- Interoperability Auto-Test
The purpose of Interoperability test: check the different mode, version of EVSE and EV to realize charging interconnect ability via information exchange and process control.
On-Board Inverter Auto-Test with Feedback Function
Programmable AC/DC source can provide 400~1000V high voltage to test EV on-board DC-DC, at this moment active DC load simulates the DC power consumer of the EV eg. DC motor. The power can be feedback to grid to reduce the active power loss.
Ask for a pilot test or need a online demo?
Contact info@relaytest.com now
Check more information on https://www.ponovo.net/power-amplifier-for-real-time-dynamic-simulation/4-quadrant-power-amplifier/
|
|
|
|
Product Image
|